| product Category | product picture | Brief product description | manuf. web site |
|---|---|---|---|
Mechanical Liquid Level Switches |
![]() |
Density range: ≥0,7 kg/dm3 Material: SS, Aluminium bronze, sea water resistant Max. temperature: 250 °C Max. pressure: 2 500 kPa Connection: flange, BSP, NPT |
kobold.com |
Tuning Fork Liquid Level Switches |
![]() |
Max. viscosity: 5 000 mm2/s Output: Electronic switch Material: SS Max. temperature: 130 °C Max. pressure: 4 500 kPa Connection: flange, BSP, NPT, TriClamp, hygienic Ex-proof: ATEX |
kobold.com |
Nuclear |
![]() |
Detectors: GM, Scintillation Counter, Super-Sens Housing material: SS Max. temperature: 60 °C, opt. water cooling Evaluation Unit: 19" rack mounting, opt. wall mounting Required power 18 - 30 V DC, opt. 110/230 V Output: 3 relay (alarm, failure, warning) Display: 2 lines LCD Set-up: fully programmable ATEX |
bertholdtech.com |
By-pass |
![]() |
Max. measuring length: 6 m, >6 m = 2-parts Max. viscosity: 200 mm2/s Min density: 0,4 kg/dm3 Accuracy: ± 5 mm of range Material: SS Max. temperature: 400 °C Max. pressure: 32 000 kPa Connection: flanges DIN or ANSI Optional: analogue output; alarm contacts Ex-proof: ATEX |
heinrichs-mt.com |
Level or Interface Indicator for Liquids |
![]() |
Max. measuring length: 6 m Density range: 400 - 2 000 g/l Accuracy: ± 5 mm of range Material: SS, Hastelloy C Max. temperature: 250 °C Max. pressure: 32 000 kPa Connection: flanges DIN or ANSI Optional: analogue output; alarm contacts HART®, Profibus PA®, Fieldbus, ATEX |
heinrichs-mt.com |
Capacitive Level Sensors for Liquids |
![]() |
Max. measuring length: 4 m Accuracy: ± 2 mm of range Material: SS with PTFE or PVDF coating Max. temperature: 125 °C Max. pressure: 1 000 kPa Connection: BSP, NPT Required power: 12 ... 30 V DC Ex-proof: ATEX |
kobold.com |
Nuclear Level Gauges |
![]() |
Point detector: Scintillation Counter NaI(Ti) Crystal size: 25/25, 40/35 or 50/50 Automatic drift compensation Housing material: SS Max. temperature: 60 °C, opt. water cooling Evaluation Unit: 19" rack mounting, opt. wall mounting Required power 18 - 32 V DC, opt. 110/230 V Signal output: analogue and digital Display: 4 lines LCD Set-up: fully programmable Interface: RS 232 & RS 485 ATEX |
bertholdtech.com |
Nuclear Level Gauges |
![]() |
Rod detector: Plastic Scintillation Counter Detector length: 500 mm to 2 000 mm
Automatic drift compensation Housing material: SS Max. temperature: 55 °C, opt. water cooling Evaluation Unit: 19" rack mounting, opt. wall mounting Required power 18 - 32 V DC, opt. 110/230 V Signal output: analogue and digital Display: 4 lines LCD Set-up: fully programmable Interface: RS 232 & RS 485 ATEX |
bertholdtech.com |
"Uni-Probe" |
![]() |
This combined level detector/transmitter may be used as a point detector, serving as a level switch, or in conjunction with a rod source as a continuous level transmitter. The "Uni-Probe" may also be use as a rod detector (maximum length: 2 m) for continuous level measurement. Point Detector: Scintillator 50/50 NaI Crystal Sensitivity: 0,5 µSv/h for 300 cps Rod Detector: Plastic scintillator Detector length: 500 mm to 2 000 mm Signal output: analogue and digital Housing material: SS 316 Ti Max. temperature: 50 °C, opt. water cooling Required Power: 18-32 V DC or 95-250 V AC HART®, ATEX, Profibus PA, Fieldbus. |
bertholdtech.com |
"Tower-Sens" |
![]() |
Each "Tower-Sens" system could consists of a basic module and several extension modules, depending on the measuring length. The basic module includes a plastic scintillator rod and the entire electronic of the measuring system plus the communication interface. The extension module consists of a plastic scintillator rod encapsulated in SS and is coupled optically & mechanically with the basic module or another extension module. Basic module length: Either 1 or 2 m Extension module length: 2 m Maximum measuring length per system: 8 m Sensitivity: 0,5 µSv/h for 300 cps Signal output: analogue and digital Housing material: SS 316 Ti Max. temperature: 50 °C, opt. water cooling Required Power: 18-32 V DC or 95-250 V AC Interface: RS 232 & RS 485 HART®, Profibus PA®, Fieldbus, ATEX |
bertholdtech.com |
Nuclear Mould |
![]() |
Detectors:
Scintillators Csl 40/50 or 25/50 Max. Sensitivity: 5,1 µSv/h for 300 cps Max. temperature: 50 °C, opt. water cooling Protected against electromagnetic fields Housing material: SS316 Ti Extremely fast: cycle time of 5 ms Evaluation unit: 19" module Up to 4 measuring channels Signal output: analogue and digital Required Power: 90 - 260 V AC Software: Windows CE Interface: RS 485, Profibus DP®, |
bertholdtech.com |
Eddy Current Mould Level Gauge |
![]() |
Measuring principle: A coil within the sensor generates an electromagnetic field. As a result eddy currents are induced in the top layer of the molten steel. These eddy currents in turn generate a counteracting electromagnetic field at the sensor - its strength is directly proportional to the distance between the molten steel surface and the sensor coil. Sensor dimensions: 63 x 150 x 540 mm Max. temperature: 180 °C, opt. water cooling Measuring range: 10 to 200 mm Accuracy: ± 0,2 mm of nominal range Response time: 50 ms or higher, adjustable Evaluation unit: 19" module Up to 4 measuring channels Signal output: analogue and digital Required Power: 90 - 260 V AC Software: Windows CE Interface: RS 485, Profibus DP®, |
bertholdtech.com |